Explosion-proof motors type ADVK

Is Negotiable

Contact information

Zhirov Leonid Vladimirovich

Head of Sale and Marketing Department
+380950588685, +380622032095
Email

Payment Types
Prepayment
Transportation Types
Automobile transport | Railway transport
Incoterms 2010
EXW
Packaging Types
no
Minimum Order Size
from 3

Asynchronous motors of ADVR and ADVRP types are designed for operation from a 50 Hz alternating current network as a drive for various mechanisms in mines that are dangerous for the content of mine gas (methane) and (or) coal dust in accordance with the "Safety Rules for Coal Mines" NPAOP 10.1-1.01-05. Engines ADVR-M are designed for driving fans of local airing.

Type of climatic design of engines which are manufactured for the domestic market is U2, 5 and for delivery to the CIS countries - U2.5; UHL2.5 in accordance with GOST 15150.

The engines satisfy the requirements of GOST 183, GOST 22782.0, GOST 22782.5, GOST 22782.6, GOST 24719, GOST R 51330.0, GOST R 51330.1, GOST R 51330.10, GOST R 51330.20.

The motors are manufactured for voltage 1140, 660, 380 V.

Method of cooling of engines - IСА0141 according to GOST 20459.

The level of protection of motors and terminal boxes is IP54 according to GOST 17494, GOST 14254, external fan (if any) on the side of the air inlet - IP20.

The motors have thermal protection of stator windings of type TP111 in accordance with GOST 27888 and GOST 27917. The electric circuit of thermal protection is intrinsically safe according to GOST 22782.5 (ia according to GOST R 51330.10). The temperature is 160-165 ° C for the insulating class H and 140-145 ° C for the insulation class F.

Type and level of explosion protection of engines:

RV 3VIa - for deliveries to the domestic market;

РВ ЕхdіаI - for export to the CIS countries.